From a Hand Sketch to a Complete Collection System
Published
A plant doesn't need a finished drawing to start a conversation about fume and dust collection. What we often receive is a hand sketch: the shop outline, a grid of weld stations, a few key dimensions, and a blower and filter station marked off to one side.
That sketch is the starting point. Indventech supplies fans, dust and fume collectors, duct and capture devices such as drops, fume arms and hoods. We apply engineering know-how to those products so they work as one system, sized and arranged around how the shop actually runs.

What the customer sent
The sketch in this example is a weld shop laid out on graph paper. It shows the front of a shop about 146 feet across, a grid of weld stations, and the blower and filter station to one side. It does not show duct sizes, a fan selection or how fume will be captured at each table. Those decisions come next.
What the engineering adds
A fan, a collector, a run of duct and a capture device at the table each do a job. They only work as intended when they are selected, sized and arranged together. This is the application work we do with a sketch like that:
- Size the collector and fan for the airflow every station needs and the resistance of the duct run.
- Lay out a duct network that steps down in size as air is drawn off at each branch, holding transport velocity so dust and weld-fume particulate don't settle in the duct.
- Add branch takeoffs and a slide gate on every drop so the system can be balanced and unused stations can be shut off.
- Choose the capture device at each station. In this layout that means drops at the tables. Where the work fits them better, we may specify fume arms, hoods or downdraft tables instead.
The 3D views here are an illustrative layout based on that sketch.
The layout
A central collector and blower sit at the blower and filter station marked on the sketch. A 30-inch flanged main leaves the collector and feeds 24-inch trunk lines. From the trunks down, the duct is clamp-together. Those trunks supply seven branch lines that taper from 24 inches down to 9 inches, with 45-degree takeoffs at the branches.

From each branch, 9-inch verticals drop to Y fittings, and each Y splits into two 6-inch drops, one per weld station. The layout serves 112 stations, and every drop has its own slide gate for balancing and shutoff.

This layout uses drops at the tables. Other shops may be better served by fume arms, hoods or downdraft tables. The idea is the same: pick the capture device that fits the process, then connect it to a collector, fan and duct system that are sized and balanced together.
Working alongside your team
We select, supply and apply this equipment as one system. When it is time to install and start up, we work alongside the customer's contractors and maintenance team. We do not replace them.
Got a sketch of your shop?
If you have a weld shop or other process area that needs collection, a simple sketch is enough to start. Send us what you have, and we'll look at how to apply the right collector, fan, duct and capture devices to the way your plant runs.